LEVEL
3 SPECIFICATIONS:
(All measurements are traceable to NIST
standards.)
Ø
Mass
Flow Rate:
Range as previously mentioned,
+/-0.4% of reading.
Ø
Repeatability: <
+/-0.25% as defined as 2 standard deviations
divided by the mean of 20 identical samples.
Ø
UUT
Voltage: 0-5
VDC, +/- 0.02% Full Scale.
0-10 VDC +/- 0.02% Full Scale.
Ø
UUT
Frequency: 0
to 20 kHz, 50 ppm.
Ø
UUT
Pressure:
0-15psia, +/-0.02% Full Scale.
Ø UUT
Temperature:
+/-0.5°F.
|
Level
2 - Semi - Automated System |

The
user provides the desired Mass Flow via
Ethernet command or FLOW SYSTEMS software
interface. The system, FC500-FC Flow
Controller, will set and record the Mass
Flow Rate, MAFS voltage, and ambient test
conditions (T and RH, P optional.)
|

FEATURES
Custom LabVIEW® Software for:
Ø
Mass
Flow Setpoint.
Ø
Display
of Results and Stability.
Ø
Data
Logging.
Ø
12vdc
Power Supply Optional.
Ø
PC
Optional.
Ø
Frequency
Measurement Optional.
Ø
Internet
Diagnostics Optional.
|
LEVEL 2 SPECIFICATIONS:
(All measurements are traceable to NIST
standards.)
Ø
Mass
Flow Rate:
Range as previously mentioned,
+/-0.54% of reading.
Ø
UUT
Voltage: 0-5
VDC, +/- 0.03% Reading.
0-10 VDC +/- 0.03% Reading.
Ø
UUT
Frequency: Optional,
100 to 20 kHz, +/-0.01 Hz.
Ø
UUT
Pressure:
Optional, 0-15psia, +/-0.05% of
Full Scale.
Ø UUT
Temperature:
+/-0.5°F.

|