Test Set-up Screen:
Configures the
FC200 for meter type, fluid, and units.
Real
Gas Properties for most Gasses.
Flowmeter Configuration:
Calculations for Sonic Nozzles are in accordance with ASME
MFC-7M / ISO 9300.
Computations for Sub-Sonic Venturis meet the requirements of ASME MFC-3M / ISO 5167.
Iterative
Solution for Discharge Coefficient (Cd)
based on Actual Calibration Data or
Theoretical Models.
Data Monitoring and Logging:

Data
may be logged automatically at a
user-defined interval.
Flow Totalizing /
Batching: Allows the User to Start, Stop, Clear, and Log Batch
Data.
Calibration Assistant for Maintenance of Internal Instrumentation:

Optional
Internet Support and Diagnostics:
Allows FLOW SYSTEMS to observe and / or control a system remotely for training, optimization, or troubleshooting purposes.
This service requires a temporary, high-speed data line.
SPECIFICATIONS:
| Model
Code |
Meter
Type Supported |
| FC200-CFV |
Sonic
Nozzle |
| FC200-VEN |
Venturi |
| Options |
|
-01
Humidity Sensor (Atmospheric Air) |
|
-02
Dew Point Sensor (Compressed Air) |
Accuracy
The FC200 uses a 16-bit data acquisition system to measure all analog inputs. The following tables
state percent of reading and mass flow accuracy for both available meter types and corresponding instrumentation configurations.
Sonic Nozzles
| Configuration |
Mass Flow Accuracy |
Comments |
| Level 1 |
+/-6.45% of Reading |
Assumes:
diameter 0.031" uncalibrated nozzle, 6:1 pressure range (+/-0.1% full scale) & 40° to 100°F gas temperature. |
| Level 1 |
+/-0.88% of Reading |
Assumes:
diameter 0.50" uncalibrated nozzle, 6:1 pressure range (+/-0.1% full scale) & 40° to 100°F gas temperature. |
| Level 2 |
+/-0.56% of Reading |
Assumes:
+/-0.50%
CEESI calibration, 6:1 pressure range (+/-0.04% full scale) & 40° to 100°F gas temperature. |
| Level 3 |
+/-0.29% of Reading |
Assumes: +/-0.25% CEESI calibration, 6:1 pressure range (+/-0.02% full scale) & 40° to 100°F gas temperature. |
|
An optional
humidity sensor is available for moist air applications.
|
Sub-Sonic Venturis
| Configuration |
Mass Flow
Accuracy |
Comments
|
| Level 1 |
+/-1.41% of Reading |
Assumes: Uncalibrated
Venturi, 6:1 pressure range (+/-0.1% full scale), 10:1 Dp range (+/-0.3% of reading) & 40° to 100°F gas temperature. |
| Level 2 |
+/-0.61% of Reading |
Assumes: +/-0.5%
CEESI calibration, 6:1 pressure range (+/-0.04% full scale), 10:1 Dp range (+/-0.3% of reading) & 40° to 100°F gas temperature. |
| Level 3 |
+/-0.43% of Reading |
Assumes: +/-0.25% CEESI calibration, 6:1 pressure range (+/-0.02% full scale), 10:1 Dp range
(+/-0.3% of reading) & 40° to 100°F gas temperature. |
|
An optional
humidity sensor is available for moist air applications.
|
Connections - Bench Top or Rack Mount:

| Power
Requirements: |
100-240 VAC /
50 - 60Hz / 1 Phase / 1 AMP |
|
Communication:
|
USB
|
|